This site currently shows sample data for demonstration.

Vulnerabilities

CVE-2017-13997 | BDVDB-2026-91134 Detail

Schneider Electric InduSoft Web Studio, InTouch Machine Edition

Description#

A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server.

Impact#

No impact statement in the source data.

Weaknesses#

  • CWE-306 Missing Authentication for Critical Function

References#

Exploit#

No public exploit known

History#

  1. Version 1Record published in the CVE List.
  2. Version 2Most recent update recorded in the CVE List.