This site currently shows sample data for demonstration.

Vulnerabilities

CVE-2026-4638 | BDVDB-2026-378488 Detail

PaesslerPRTG Network Monitor

Description#

PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter.  Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.

Impact#

CAPEC-54 Query System for Information

Weaknesses#

  • CWE-209 Generation of error message containing sensitive information

References#

Exploit#

No public exploit known

History#

  1. Version 1Record published in the CVE List.