This site currently shows sample data for demonstration.

Vulnerabilities

CVE-2026-48021 | BDVDB-2026-352263 Detail

med-unitedepa4all

Description#

In epa4all, prior to version 2026-05-20, an attacker who can intercept the TLS connection between epa4all and the ePA backend can complete the VAU handshake with attacker-controlled keys and obtain the session encryption keys. All inner HTTP traffic (patient consent decisions, medication data, document operations, authorization tokens, and entitlement queries) becomes readable and modifiable. The attacker can also inject arbitrary requests through the hijacked channel. This issue has been patched in version 2026-05-20.

Impact#

Per CVSS v3.1: confidentiality impact high, integrity impact high, availability impact none. Attack vector: network.

Weaknesses#

  • CWE-295 Improper Certificate Validation
  • CWE-347 Improper Verification of Cryptographic Signature

References#

Exploit#

No public exploit known

History#

  1. Version 1Record published in the CVE List.
  2. Version 2Most recent update recorded in the CVE List.