This site currently shows sample data for demonstration.

Vulnerabilities

CVE-2026-25599 | BDVDB-2026-337010 Detail

Orca EnergyOrca heat pump

Description#

Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.

Impact#

Per CVSS v3.1: confidentiality impact low, integrity impact low, availability impact low. Attack vector: network.

Weaknesses#

  • CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
  • CWE-306 Missing Authentication for Critical Function
  • CWE-319 Cleartext Transmission of Sensitive Information

References#

Exploit#

No public exploit known

History#

  1. Version 1Record published in the CVE List.