This site currently shows sample data for demonstration.

Vulnerabilities

CVE-2025-27769 | BDVDB-2026-319407 Detail

SiemensHeliox Flex 180 kW EV Charging Station

Description#

A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable.

Impact#

Per CVSS v3.1: confidentiality impact low, integrity impact none, availability impact none. Attack vector: physical.

Weaknesses#

  • CWE-923 Improper Restriction of Communication Channel to Intended Endpoints

References#

Exploit#

No public exploit known

History#

  1. Version 1Record published in the CVE List.