This site currently shows sample data for demonstration.

Vulnerabilities

CVE-2025-58405 | BDVDB-2026-317892 Detail

CGMCGM CLININET

Description#

The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP security headers nor HTML-based frame‑busting protections were detected. As a result, an attacker can embed the application inside a maliciously crafted IFRAME and trick users into performing unintended actions, including potentially bypassing CSRF/XSRF defenses.

Impact#

Per CVSS v4.0: confidentiality impact none, integrity impact low, availability impact none. Attack vector: network.

Weaknesses#

  • CWE-1021 Improper Restriction of Rendered UI Layers or Frames

References#

Exploit#

No public exploit known

History#

  1. Version 1Record published in the CVE List.