This site currently shows sample data for demonstration.

Vulnerabilities

CVE-2024-32850 | BDVDB-2026-238049 Detail

Seiko SolutionsSkyBridge MB-A100/MB-A110

Description#

Improper neutralization of special elements used in a command ('Command Injection') exists in SkyBridge MB-A100/MB-A110 firmware Ver. 4.2.2 and earlier and SkyBridge BASIC MB-A130 firmware Ver. 1.5.5 and earlier. If the remote monitoring and control function is enabled on the product, an attacker with access to the product may execute an arbitrary command or login to the product with the administrator privilege.

Impact#

Per CVSS v3.1: confidentiality impact high, integrity impact high, availability impact high. Attack vector: network.

Weaknesses#

  • CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

References#

Exploit#

No public exploit known

History#

  1. Version 1Record published in the CVE List.
  2. Version 2Most recent update recorded in the CVE List.