CVE-2022-27221 | BDVDB-2026-178016 Detail
SiemensSINEMA Remote Connect Server
Description#
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). An attacker in machine-in-the-middle could obtain plaintext secret values by observing length differences during a series of guesses in which a string in an HTTP request URL potentially matches an unknown string in an HTTP response body, aka a "BREACH" attack.
Impact#
Per CVSS v3.1: confidentiality impact high, integrity impact none, availability impact none. Attack vector: network.
Weaknesses#
- CWE-203 Observable Discrepancy
References#
Exploit#
No public exploit known
History#
- Version 1Record published in the CVE List.
- Version 2Most recent update recorded in the CVE List.